Sponsored Links

Minggu, 15 Juli 2018

Sponsored Links

Total Freedom Wellness Spa | body-vibration-therapy-prattville ...
src: www.totalfreedomwellnessspa.com

Whole body vibration (WBV) is a generic term used when vibrations (mechanical oscillations) of any frequency are transferred to the human body. Humans are exposed to vibration through a contact surface that is in a mechanical vibrating state. Human's are generally exposed to many different forms of vibration in their daily lives. This could be a driver's seat, a moving train platform, through a power tool, a training platform, or one of countless other devices. It is a potential form of occupational hazard, particularly after years of exposure.

When high frequency vibrations (above 50 Hz) enter though the hands, occupational safety concerns may arise. For example, when working with a jackhammer and the development of vibration white finger. Exposures and limits have been estimated in the ISO 5349-1 for hand-transmitted vibration.

Whole body vibration training as a form of physical exercise can offer some fitness and health benefits, but it is not clear if it is as beneficial as regular physical exercise. A review in 2014 came to the conclusion that there is little and inconsistent evidence that acute and/or chronic whole body vibration could improve the performance of competitive and/or elite athletes.


Video Whole body vibration



As a hazard

Humans are sensitive to mechanical oscillations ranging in frequency from well below 1 Hz up to 100 Hz. Lower frequencies of vibration lead to human motion sickness while higher frequencies can lead to general annoyance and discomfort. The minimization of discomfort due to vehicle vibration is important in the automotive industry where ride quality is important. Discomfort and even pain may extremely prevalent in situations where medically injured patients are transported. The discomfort due to vibration can estimated in various environments.

Workplace exposure

Workplace exposures to whole-body vibrations for long durations can lead to musculoskeletal problems of many kinds. Problems of the neck and lower back in particular can be common for operators of heavy equipment including construction, forestry, agriculture, and trucking. Other occupations where whole-body vibrations may be present include operatorsof aircraft, workers on-board sea vessels, drivers of public transportation including trains and buses among others.

Farmers with long-term exposure to whole body vibration and mechanical shocks have a higher prevalence of back pain (compared to those not exposed to vibration), and the prevalence increases with vibration dose. Long-term exposure affecting the whole body leads to spinal degeneration (spondylosis) and increased risk of low back pain.

Factors that affect the occupational exposure to whole-body vibration include the frequency of vibrations, the magnitude of vibrations, the daily exposure to vibrations, the standing or seating posture of the operator, the direction of the vibration, and how tightly coupled the human is to the source of the vibration. Exposure limits and estimates have been characterized in the ISO 2631-1 for whole-body vibration. Measurements of vibration exposure are usually taken at the human/vibration interface.

Patient transport

Injured patients can be exposed to shocks and vibrations during transport which can worsen patient conditions due to involuntary motions of the body. Many forms of immobilization devices are used to limit this motion with varying degrees of success. Common modes of patient transport include hand carried stretcher (litter), ground ambulance, and air medical services which all contain multiple forms of shocks and whole-body vibrations.

Measurement

Measurements are taken with accelerometers to estimate the amount of vibration exposure to the human body. These measurements are taken at the human body or at the vibration source or surface. Measurements of different directions are taken to relate the motion direction with the response of the human body. Specifically, transfer functions can be used to determine the human response to the vibration. Measurement techniques for estimating exposures to whole body vibrations and hand-arm vibration have been developed in International Standards.


Maps Whole body vibration



Vibration training

Vibration training is the deliberate exposure to the body of varying frequencies/amplitudes/forces using certain joint angles for any limited time (approximately 1 minute sets). It is also known as vibration therapy, biomechanical stimulation (BMS), mechanostimulation and biomechanical oscillation (BMO). It employs low amplitude, low frequency mechanical stimulation. It can be pivotal (vibrating from side to side) or lineal (vibrating up and down).

History

The immediate predecessor of modern vibration training is Rhythmic Neuromuscular Stimulation (RNS). In former East Germany Biermann was experimenting with the use of cyclic massage and its effects on trunk flexion back in the sixties (Biermann, 1960).

The technique has been tested on turkeys in the hope of finding a benefit that could be used for astronauts. For the used technology an engineering issues came into play when they tried to upgrade the machine to take the weight of a human being. Once the vibration intensity grew strong enough to lift over 40 kg, fractures appeared in the steel. Using a different mechnanical stimulation approach the first bedrest study using a vibration training device for humans was done by the European Space Agency (ESA) in 2003 in Berlin (Berlin Bedrest Study, BBR). The same technology was then used in several parabolic flight campaigns of the DLR (German Aerospace Agency) starting in 2006 where the feasibility of use of a lightweight vibration training device under microgravity conditions was demonstrated and ein 2009 and 2010 where basic research on influence of microgravity on vibration training effects was investigated.

NASA, since 1961, has been doing tests at adding light vibrations to pre-existing exercise equipment's and systems to minimize vibration transmission of existing exercise devices to the space station like the Treadmill Vibration Isolation System (TVIS) and the Cycle Ergometer Vibration Isolation System (CEVIS). Any company referencing NASA directly in its marketing campaigns is highly misleading and has no relevance to the discipline of vibration training.

The first Galileo machine patent was filed in 1996 in the same year the first Galileo device was commercially available. In 1996 the first Galileo vibrating dumbbell patent was filed.

Training effects

According to Mayo Clinic, whole body vibration can offer some fitness and health benefits, but it is not clear if it is as beneficial as regular physical exercise. A review in 2014 came to the conclusion that there is little and inconsistent evidence that acute and/or chronic whole body vibration could improve the performance of competitive and/or elite athletes.

Cochrane reviews have concluded that there is insufficient evidence of effect of whole body vibration training on functional performance of people with neurodegenerative disease, or in disease-related problems in people with fibromyalgia.

Vibrating platform types

Vibrating platforms fall into different, distinct categories. The type of platform used is a moderator of the effect and result of the training or therapy performed (Marin PJ, Rhea MR, 2010). Main categories of machine types are:

  1. High Energy Lineal, found mostly in commercial vibration training studios and gyms. The vibration direction is lineal/upward
  2. Premium Speed Pivotal, (teeter-totter movement) used for physiotherapy work at lower speeds and exercise workouts at "premium" speed, up to 30 Hz. Both commercial and home units are available.
  3. Medium Energy Lineal, the majority of lineal platforms produced. These are usually made of plastic; some have 3-D vibration which is low quality.
  4. Low Speed Pivotal units.

Other machine types are low Energy/Low amplitude lineal and Low energy/High amplitude lineal.

Concerning the z-movements, two main types of system can be distinguished (Marin PJ et al. 2010, Rittweger 2010, Rauch 2010) :

  • Side alternating (pivotal) systems, operating like a see-saw and hence mimicking the human gait where one foot is always moving upwards and the other one downwards, and
  • Linear systems where the whole platform is mainly doing the same motion, respectively: both feet are moved upwards or downwards at the same time.

Systems with side alternation usually have a larger amplitude of oscillation and a frequency range of about 5 Hz to 40 Hz. Linear/upright systems have lower amplitudes but higher frequencies in the range of 20 Hz to 50 Hz. Despite the larger amplitudes of side-alternating systems, the vibration (acceleration) transmitted to the head is significantly smaller than in non side-alternating systems (Abercromby et al. 2007) while at the same time muscle activation even at identical vibration parameters are increased in pivotal systems.

Mechanical stimulation generates acceleration forces acting on the body. These forces cause the muscles to lengthen, and this signal is received by the muscle spindle, a small organ in the muscle. This spindle transmits the signal through the central nervous system to the muscles involved (Abercromby et al. 2007, Burkhardt 2006).

Power Plate is a brand of vibrating platform consisting of a vibrating base, which may vibrate up and down approximately 1 to 2 millimetres (39 to 79 thou) (1/16") 25 to 50 times per second. The machine is large enough to accommodate a person in deep squat. Traditional exercises such as squats and push-ups can be done on the vibrating base.

Galileo (in the US up until 2014 also available as Vibraflex) is a brand of vibration training platforms used as exercise equipment as well as for therapeutic use. It consists of a vibration platform which vibrates sinusoidal side alternating like a see-saw. Depending on the device size it oscillates with an amplitude of up to 6 mm (equivalent to a peak to peak distance of 12 mm) and a frequency of 5 Hz to 40 Hz (5 to 40 repetitions per second). Galileo is manufactured in Germany by the German company Novotec Medical GmbH. Since 2004 Galileo is also available as a medical device.

The base plate of Galileo vibration training devices is moving like a see-saw. This side alternating motion is supposed to mimic human gait in order to utilize nearly physiological motion patterns close to the side alternating human gait. The side alternation causes the hip to tilt which requires the contra lateral muscles of the back to be activated - while one leg is lifted the other drops. Compared to vertically vibrating devices the side alternating motion results in very low acceleration acting on the centre of gravity of the upper body and the head.

Belts

A vibrating belt machine (also Mueller belt machine, belt massager, or jiggler machine) is an exercise machine that uses a vibrating belt, to be used around the waist or buttocks.


calf stretch #exercise | Hypervibe Whole Body Vibration #WBV ...
src: s-media-cache-ak0.pinimg.com


See also

  • Hand-arm vibration
  • Noise, vibration, and harshness

AcuVibes quick Whole Body Vibration workout on portable WBV ...
src: i.ytimg.com


References


Industrial machine bloggers should definitely look into whole body ...
src: www.wordpressthemeshock.com


Further reading

Source of the article : Wikipedia

Comments
0 Comments